Pipe spacing: 10, 15 or 20 cm

Spacing is the distance between neighbouring pipes. The closer they are, the more heat the floor gives off at the same water temperature, but the more pipe and loops you need.

SpacingWhere it is usually usedPipe per m²
10 cmBathrooms, rooms with large windows, edge zones10 m
15 cmBedrooms, living rooms, kitchens6.7 m
20 cmStorage rooms, rooms with low heat loss5 m

Heat pumps: lower temperature, closer spacing

A heat pump works most efficiently with a low flow temperature, around 30–35 °C. For the floor to give off enough heat at that temperature, 10–15 cm spacing is the usual choice rather than 20 cm.

Edge zones by windows

Heat loss is greatest along outside walls and large windows. Under EN 1264 the pipes in a strip up to 1 m wide along them can be laid closer, for example every 10 cm, with 15 cm in the rest of the room.